Configurable Alarm Severity (Interface Alarm)
SHOW ALARMS
Syntax
SHOW ALARMS [ { ALL | CARD={ slot-list | ACTCFC | INACTCFC | ALL }
| INTERFACE={ type:id-range | id-range | ifname-list | ALL } } ] [
SEVERITY={ CRITICAL | MAJOR | MINOR | INFO | ALL } ] [ FULL ]
Displays alarm conditions on system components. The display is filtered according to the
Description
given parameters and shown in a tabular output, with one alarm per row. There are 4 col-
umns of output for each alarm consisting of:
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
Option
ALARMS
INTERFACE
SEVERITY
FULL
Example
SHOW ALARMS ALL
E135 - manager SEC>> SHOW ALARMs CARD=1 FULL
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
The component the alarm is against
A description of the fault or condition
The severity of the alarm
The time and date the alarm occurred.
Description
The type of alarms to display
ALL
CARD
ACTFCF
INACTCFC
ALL
The interfaces that will have their alarms displayed.
The severity of the alarm
CRITICAL
MAJOR
MINOR
INFO
ALL - All severities
Makes SHOW ALARMS show all alarms regardless of
whether or not they are masked
Introduction
Default Value
ALL
Info
ALL
8-11