Technology > Fixing > Controls > Fixing temperature control
● Temperature control during startup
Temperature is controlled to reach the standby temperature.
80
70
60
50
Low temperature environment
40
startup mode
30
20
10
0
5
10
15
Environment temperature (deg C)
<Normal startup mode>
In the case of reaching the target temperature within 30 seconds due to quick temperature
rise of the Fixing Roller, the target temperature is maintained to be shifted to the ready
state once the potential control is completed.
Conditions
Environment
Environment
Fixing Roller
temperature
humidity
temperature
17 deg C or
Low humidity
70 deg C or
more
environment(within
less
13g of absolute
moisture content)
NOTE:
In the case of selecting the fixing improvement mode in the following service mode, the
machine does not enter the startup state for 30 seconds and waits until the specified
time.
COPIER> OPTION> BODY> FSPD-S1 :Selection of fixing improvement mode
2
Technology > Fixing > Controls > Fixing temperature control
High humidity environment
startup mode
Normal startup mode
20
25
30
35
F-2-132
Target
Target
temperature
temperature
reaching
time
Japanese model
30 sec
imageRUNNER ADVANCE
6055: 180 deg C
T-2-55
<Low temperature environment startup mode>
After it reaches the target temperature, the target temperature is maintained until
completion of the potential control, and then the machine enters ready state.
Conditions
Environment
Environment humidity
temperature
Less than 17
-
70 deg C or less 195 deg C
deg C
<High humidity environment startup mode>
After it reaches the target temperature, the target temperature is maintained until
completion of developing idle rotation as well as completion of the potential control, and
then the machine enters ready state.
Conditions
Environment
Environment humidity
temperature
-
High humidity
70 deg C or less 185 deg C
environment(13g or more
of absolute moisture
content)
<Recovery mode>
The machine enters ready state once it reaches the target temperature.
Conditions
Environment
Environment
Fixing Roller
temperature
humidity
temperature
-
-
70 deg C or
more
Target
Target
Fixing Roller
temperature
temperature
temperature
reaching time
75 sec
(reference value)
Target
Target
Fixing Roller
temperature
temperature
temperature
reaching time
75sec
<imageRUNNER
(reference value)
ADVANCE
6055 Japanese
model:180 deg
C>
Target temperature
Target
temperature
reaching time
Environment Temperature: 17
30 sec or less
deg C or more
Japanese: 180 deg C
(imageRUNNER ADVANCE
6055: 175 deg C)
Non Japanese: 185 deg C
Environment Temperature: less
than 17 deg C
Japanese: 190 deg C
Non Japanese: 195 deg C