Technology > Image Formation System > Controls > Image Stabilization Control
Standard
Warm-up rotation
duration
Control
Normal
(second)
At
startup
Approx.
startup*
**
Idle Rotation
at First in
15(30)
(○)*12
○
the Day (H/H
environment)
Contrast
Potential
1
×
○
Correction at
Startup
Disengagement
1
○
○
of Transfer Unit
Weak Bias
Control at
×
×
Leading Edge
Black Band
Control
10
×
×
2
Technology > Image Formation System > Controls > Image Stabilization Control
Timing
Initial
Paper
rotation
interval
power
Door
Jam
OFF/
open
recovery
ON***
×
×
×
×
×
×
×
×
×
×
○
○
○
○
×
×
×
×
○
○
×
×
×
×
×
Last
Interruption
Arbitrary
rotation
Forcible
PASCAL
interruption
Low duty
Normal
(Full
at 2,000
ejection
correction)
correction)
sheets
×
×
×
×
×
×
×
×
○
○
○
○
×
×
×
×
×*13
*14
×
×
Remarks
PASCAL
(Quick
*12 Only when the environment is in high temperature /
humidity
×
×
At jam recovery / after patch generation / at job completion
○
×
*13 At last rotation after the predefined sheets processed
following the last black band control execution (2,000 sheets
in default)
×
*14 If the operation criteria are met during low duty ejection
control, the control is synchronized to also perform this
control.