Image Quality Troubleshooting; Iq1 Iot Image Quality Entry Rap; Iq2 Iit Image Quality Entry Rap - Xerox WorkCentre 5022 Service Manual

Hide thumbs Also See for WorkCentre 5022:
Table of Contents

Advertisement

IQ1 IOT Image Quality Entry RAP

Initial Actions
Determine whether the image quality problem occurs in Copy Mode or Printer Mode. If the
problem occurs in Copy Mode, go to [IQ2 IIT Image Quality Entry RAP].
Procedure
Determine the image quality problem and go to the relevant RAP.
Image Quality Problem
Low Image Density
Overall low density of images.
Wrinkled Image
The printed paper is creased, folded or torn.
Residual Image (Ghost-
Ghost images appear on the paper. Parts of the
ing)
previous page or current page appear as ghost
images on the paper.
Background
The whole page or part of the page is contami-
nated by toner. The contamination appears as very
light grayish color.
Deletion
Part of the image is missing.
Skew/Misregistration
Printed images are not parallel to the edges of the
paper.
Process Direction Bands,
Black lines or blank areas running along the paper
Streaks, and Smears
in vertical direction.
Unfused Copy/Toner Off-
Printed images are not properly fused onto the
set
paper. When rubbed, the image comes off easily.
Repeating Bands,
Black lines or blank areas running along the paper
Streaks, Spots, and Smear
in h.orizontal direction.
Mottle
Uneven printed image density.
Spots
Toner spots and blank areas are spread irregularly
over the whole page.
Black Prints
Paper is printed completely black.
Blank Image
Paper is printed completely white.
Version 1.0
WC 5022/5024
Table 1
Symptoms
IQ3 RAP
IQ4 RAP
IQ5 RAP
IQ6 RAP
IQ7 RAP
IQ8 RAP
IQ9 RAP
IQ10 RAP
IQ11RAP
IQ12 RAP
IQ13 RAP
IQ14 RAP
IQ15 RAP

IQ2 IIT Image Quality Entry RAP

Initial Actions
Clean the Platen Glass.
Procedure
Determine the image quality problem and go to the relevant RAP.
Image Quality Problem
RAP
Low Image Density
Background
Process Direction Bands,
Streaks, and Smears
Repeating Bands,
Streaks, Spots, and Smear
Spots
Black Prints
06/2014
3-5
Table 1
Symptoms
Overall low density of images.
The whole page or part of the page is contami-
nated by toner. The contamination appears as very
light grayish color.
Black lines or blank areas running along the paper
in vertical direction.
Black lines or blank areas running along the paper
in h.orizontal direction.
Toner spots and blank areas are spread irregularly
over the whole page.
Paper is printed completely black.

Image Quality Troubleshooting

3.1.4 Image Quality Troubleshooting
RAP
IQ3 RAP
IQ6 RAP
IQ9 RAP
IQ11RAP
IQ13 RAP
IQ14 RAP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5024

Table of Contents