Fefd Mode - Dell Z9500 Command Reference Manual

Hide thumbs Also See for Z9500:
Table of Contents

Advertisement

fefd mode

Change the FEFD mode on an interface.
Z9500
Syntax
fefd mode {normal | aggressive}]
To return the FEFD mode to the default of normal, use the no fefd mode
command.
Parameters
normal
aggressive
Defaults
normal
Command
INTERFACE
Modes
Command
This guide is platform-specific. For command information about other platforms,
History
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
9.2(1.0)
8.3.19.0
8.3.11.1
8.3.7.0
Related
Commands
1168
(OPTIONAL) Enter the keyword normal to change the link
state to "unknown" when a far-end failure the software
detects on that interface. When the interface is placed in
"unknown" state, the software brings down the line protocol.
(OPTIONAL) Enter the keyword aggressive to change the
link state to "error-disabled" when a far-end failure the
software detects on that interface. When an interface is
placed in "error-disabled" state, enter the fefd reset
command to reset the interface state.
Description
Introduced on the Z9500.
Introduced on the S4820T.
Introduced on the Z9000.
Introduced on the S4810.
fefd
— enables far-end failure detection.