9.2 RS-485 communication parameter settings
The required parameters for a single servo drive connection are: P3.000 (Address), P3.001
(Transmission speed), and P3.002 (Communication protocol). P3.003 (Communication error
handling), P3.004 (Communication timeout), P3.006 (Digital input (DI) control switch), and
P3.007 (Communication response delay time) are optional settings.
Refer to Chapter 8 for detailed descriptions of the relevant parameters.
Parameter
P3.000
P3.001
P3.002
Function
Address
Transmission speed
Communication protocol
MODBUS Communication
9