ASDA-A3
P1.098
Default:
0
Unit:
ms
Format:
DEC
Settings:
When the disconnection detection protection (UVW) function is enabled (P2.065 [Bit 9] = 1), select the
response time of the detection mode with this parameter. Set P1.098 to 0 to use the servo's default
response time.
When P1.098 is not set to 0, the range should be between 100 and 800 for the detection response time.
Note:
If it is necessary to shorten the response time, it is recommended that you use this parameter.
1.
When the servo is on and has not started running, it is recommended that you set this parameter if you need to
2.
detect disconnection.
P1.099 -
P1.100
P1.101■
Default:
0
Unit:
mV
Format:
DEC
Settings:
When you set 6 for the monitor source for P0.003 [YX], then the analog monitor output voltage refers to
the voltage value of P1.101.
P1.102■
Default:
0
Unit:
mV
Format:
DEC
Settings:
When you set 7 for the monitor source of P0.003 [YX], then the analog monitor output voltage refers to
the voltage value of P1.102.
P1.103 -
P1.110
Disconnection detection protection (UVW) response time
Reserved
Analog monitor output voltage 1
Analog monitor output voltage 2
Reserved
Control mode: All
Setting range: 0, 100 - 800
Data size:
16-bit
Control mode: All
Setting range: -10000 to 10000
Data size:
16-bit
Control mode: All
Setting range: -10000 to 10000
Data size:
16-bit
Parameters
Address: 01C4H
01C5H
Address: 01CAH
01CBH
Address: 01CCH
01CDH
8
8-65