Parameters
3: CN2
Note: when the source of Compare is the Capture axis, the source of Capture (P5.039.Y) cannot be changed.
Z: trigger logic
8
0: NO (normally open)
1: NC (normally closed)
U: trigger minimum interval (unit: ms)
Note: refer to Chapter 7 for detailed instructions for Capture.
P5.040
Default:
Unit:
Format:
Settings:
The first delay time of PR mode.
P5.041
Default:
Unit:
Format:
Settings:
The second delay time of PR mode.
P5.042
Default:
Unit:
Format:
Settings:
The third delay time of PR mode.
P5.043
Default:
Unit:
Format:
Settings:
The fourth delay time of PR mode.
8-126
Delay time after position reached (Number #0)
0
ms
DEC
Delay time after position reached (Number #1)
100
ms
DEC
Delay time after position reached (Number #2)
200
ms
DEC
Delay time after position reached (Number #3)
400
ms
DEC
Control mode: PR
Setting range: 0 - 32767
Data size:
16-bit
Control mode: PR
Setting range: 0 - 32767
Data size:
16-bit
Control mode: PR
Setting range: 0 - 32767
Data size:
16-bit
Control mode: PR
Setting range: 0 - 32767
Data size:
16-bit
ASDA-A3
Address: 0550H
0551H
Address: 0552H
0553H
Address: 0554H
0555H
Address: 0556H
0557H