Parameters
PM.019▲
Default:
Unit:
8
Format:
Settings:
The time required for the motor protection level at the normal level to reach the overload level is called
the operating time. When the protection level reaches the overload level, AL006 is triggered. The load
ratio is based on 100%. When the ratio is above 100%, it is load increase gain (PM.019); when the ratio
is less than 100%, it is load decrease gain (PM.020).
Example 1:
100%
0%
8-204
Load increase gain
100
%
DEC
Load ratio
Operating time
0
12 sec × PM.020
20%
12.3 sec × PM.020
40%
13.6 sec × PM.020
60%
16.3 sec × PM.020
80%
22.6 sec × PM.020
100%
120%
26.38 sec × PM.019
140%
35.2 sec × PM.019
160%
17.6 sec × PM.019
180%
11.2 sec × PM.019
200%
8 sec × PM.019
220%
6.1 sec × PM.019
240%
4.8 sec × PM.019
Overload (AL006)
protection counter
Applicable motor: All
Setting range:
Data size:
Load ratio
260%
280%
300%
320%
340%
N/A
360%
380%
400%
420%
440%
460%
480%
500%
T1
T2
Address: FD26H
FD27H
15 - 600
16-bit
Operating time
3.9 sec × PM.019
3.3 sec × PM.019
2.8 sec × PM.019
2.5 sec × PM.019
2.2 sec × PM.019
2.0 sec × PM.019
1.8 sec × PM.019
1.6 sec × PM.019
1.4 sec × PM.019
1.3 sec × PM.019
1.2 sec × PM.019
1.1 sec × PM.019
1 sec × PM.019
Load ratio
Load ratio
Operating level
T3
ASDA-A3
160%
100%
40%
Time

Advertisement