Parameters
Monitoring variables are described in the following table by the code sequence:
Code
8
000 (00h)
001 (01h)
002 (02h)
003 (03h)
004 (04h)
005 (05h)
006 (06h)
007 (07h)
008 (08h)
009 (09h)
010 (0Ah)
011 (0Bh)
012 (0Ch)
013 (0Dh)
014 (0Eh)
015 (0Fh)
016 (10h)
017 (11h)
018 (12h)
8-228
Variable name /
property
Feedback position
Current feedback position of the motor encoder.
(PUU) B
Unit: Pulse of User Unit (PUU).
Current coordinate of the Position command. Unit: Pulse of
User Unit (PUU).
Position command
PT mode: number of pulse commands received by the servo
(PUU) B
drive.
PR mode: absolute coordinates of the Position command.
Position deviation
Deviation between the Position command and the feedback
(PUU) B
position. Unit: Pulse of User Unit (PUU).
Feedback position
Current feedback position of the motor encoder.
(pulse) B
Unit: encoder unit (pulse).
Current coordinate of the Position command. Unit: encoder unit
Position command
(pulse).
(pulse) B
This is the command after the E-Gear ratio conversion.
Position deviation
Deviation between the Position command and the feedback
(pulse) B
position. Unit: encoder unit (pulse).
Pulse command
Frequency of the pulse command received by the drive.
frequency B
Unit: Kpps. Applicable to PT / PR modes.
Current motor speed. Unit: 0.1 rpm.
Speed feedback
This is the speed after applying the low-pass filter, which makes
B D1 Dec
it more stable.
Speed command
(analog)
Speed command from the analog channel. Unit: 0.01 Volt.
B D2 Dec
Integrated Speed command. Unit: 0.1 rpm.
Speed command
(integrated) B
Source includes analog, register, or position loop.
Torque command
(analog)
Torque command from the analog channel. Unit: 0.01 Volt.
B D2 Dec
Integrated Torque command. Unit: percentage (%).
Torque command
(integrated) B
Source includes analog, register, or speed loop.
Average load rate (moving average every 20 ms) from the
Average load rate B
servo drive. Unit: percentage (%).
Peak load rate B
Maximum load rate from the drive. Unit: percentage (%).
DC Bus voltage B
Rectified capacitor voltage. Unit: Volt.
Load inertia ratio
Ratio of the load inertia to the motor inertia. Unit: 0.1 times.
B D1 Dec
IGBT temperature B
Temperature of IGBT. Unit: °C.
Resonance frequency of the system consists of two groups of
frequencies: F1 and F2
When monitoring from the panel, press the SHF key to switch
between F1 and F2:
Resonance frequency
F2 displays zero decimal places; F1 displays 1 decimal place.
B Dec
When reading by communication (mapping parameter):
Low word returns frequency F2.
High word returns frequency F1.
Offset value between motor position and Z phase;
Z phase offset
range: -4999 to +5000.
B Dec
Where it overlaps with Z phase, the value is 0; the greater the
value, the greater the offset.
Description
ASDA-A3