Parameters
PM.032▲
Default:
Unit:
8
Format:
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor.
PM.033▲
Operation
interface:
Default:
Unit:
Setting range: 0.000 - 65.535
Format:
Example:
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor. Unit conversion between Ampere peak and Ampere RMS:
PM.034▲
Operation
interface:
Default:
Unit:
Setting range: 0.000 - 2147483.647
Format:
Example:
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor. Unit conversion between Ampere peak and Ampere RMS:
8-208
Permanent-magnet rotary motor maximum speed
-
rpm
DEC
Permanent-magnet rotary motor torque constant
Panel / software
Communication
-
-
Nm/Arms
0.001 Nm/Arms
0 - 65535
DEC
Three decimals
1500 = 1.5 Nm/Arms
1.5 = 1.5 Nm/Arms
Ampere peak ( Apk ) = Ampere RMS (Arms) × √2
Permanent-magnet rotary motor rotor inertia
Panel / software
Communication
-
-
−4
2
0.001*10
10
kg ∙ ��
0 - 2147483647
DEC
Three decimals
1500 = 1.5x10
1.5 = 1.5x10
−4
2
kg ∙ ��
Ampere peak ( Apk ) = Ampere RMS (Arms) × √2
Applicable motor: Permanent-magnet rotary motor
Setting range:
0 - 6000
Data size:
16-bit
Applicable
Permanent-magnet rotary motor
motor:
Data size:
32-bit
Applicable
Permanent-magnet rotary motor
motor:
Data size:
32-bit
−4
2
kg ∙ ��
−4
2
kg ∙ ��
ASDA-A3
Address: FD40H
FD41H
Address: FD42H
FD43H
Address: FD44H
FD45H

Advertisement