Delta ASDA-A3 Series User Manual page 472

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
Settings:
The fourth Notch filter attenuation level. Set this parameter to 0 to disable the Notch filter. For example,
if you set the attenuation level to 5, then the value is -5 dB.
P2.100
Default:
5
Unit:
-
Format:
DEC
Settings:
The fourth value of resonance width. This function is disabled if P2.099 is 0. P2.098, P2.099, and P2.100
are the fourth set of Notch filter parameters.
P2.101
Default:
1000
Unit:
Hz
Format:
DEC
Settings:
The fifth value of resonance frequency. This function is disabled if P2.102 is 0. P2.101, P2.102, and
P2.103 are the fifth set of Notch filter parameters.
P2.102
Default:
0
Unit:
-dB
Format:
DEC
Settings:
The fifth Notch filter attenuation level. Set this parameter to 0 to disable the Notch filter. For example,
if you set the attenuation level to 5, then the value is -5 dB.
P2.103
Default:
5
Unit:
-
Format:
DEC
Settings:
The fifth value of resonance width. This function is disabled if P2.102 is 0. P2.101, P2.102, and P2.103
are the fifth set of Notch filter parameters.
Notch filter bandwidth (4)
Notch filter frequency (5)
Notch filter attenuation level (5)
Notch filter bandwidth (5)
Control mode: All
Setting range: 1 - 10
Data size:
16-bit
Control mode: All
Setting range: 50 - 5000
Data size:
16-bit
Control mode: All
Setting range: 0 - 40
Data size:
16-bit
Control mode: All
Setting range: 1 - 10
Data size:
16-bit
Parameters
Address: 02C8H
02C9H
Address: 02CAH
02CBH
Address: 02CCH
02CDH
Address: 02CEH
02CFH
8
8-99