Delta ASDA-A3 Series User Manual page 587

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters
Value: 0x08
DI name
CTRG
8
Value: 0x09
DI name
TRQLM
Value: 0x0A
DI name
GTRY
Value: 0x0C
DI name
VPL
8-214
In PR mode, after selecting the PR command (POS0 - 6), the motor
operates according to the command issued by the register when this DI
is on.
In Speed and Position modes, motor torque is limited when this DI is on,
and source of the limited Torque command is the internal register or
analog voltage.
After this DI is on, it temporarily disables the monitoring function of the
gantry (synchronous motion) when P1.074 = 2 (gantry function enabled).
The axis that receives this DI stops calculating and monitoring the
deviation of the two axes.
Latch function of analog Position command. If this DI is on, position of
the motor is held at the current position when the DI is triggered. During
this DI is on, the motor does not operate even when there is a change in
the analog command. When this DI is off, the motor completes the
command that was changed during the time DI was on.
Motor position
(Turn)
Motor
position
when DI is
triggered
Voltage
when DI is
triggered
Description
Description
Description
Description
When DI is off, motor
operates to the
corresponding
position inputted by
analog
Analog input
command (V)
When DI is on,
analog input
command
changed the
amount; motor
does not move
ASDA-A3
Triggering
Control
method
mode
Rising-edge
PR
triggered
Triggering
Control
method
mode
Level
PT, PR, S
triggered
Triggering
Control
method
mode
Rising-edge
PT
triggered
Triggering
Control
method
mode
Level
PT
triggered