ASDA-A3
P1.019
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
X
Additional function for Capture
Y
Reserved
X: additional function for Capture
Bit
0
1 - 3
Z: additional function for Compare
Bit
0
automatically
1 - 3
P1.020
Default:
0
Unit:
Pulse unit of capture source
Format:
DEC
Settings:
When the Capture function is enabled and set to capture multiple points (P5.038 > 1), the system stops
receiving the DI captured signal within this range once the data is captured. The DI captured signal
received within this range is not recognized as valid. Use this function to avoid the system seeing noise
as effective signals within the non-capture range.
Capture / Compare additional function settings
Function
Set this bit to 0 to disable this function. When the number of capturing times
(P5.038) is 0, capturing is complete.
Cycle
Set this bit to 1 to enable this function. When the number of capturing times
mode
(P5.038) is 0, it automatically resets the number of capturing times to the
default setting.
Reserved
-
Function
Set this bit to 0 to disable this function and the value of P1.024 remains.
P1.024 is
reset to 0
Set this bit to 1 to enable this function and P1.024 automatically resets to 0
after taking effect once.
Reserved
-
Capture - masking range
Control mode: All
Setting range: 0x0000 - 0x0101
Data size:
16-bit
Z
Additional function for Compare
U
Reserved
Description
Description
Control mode: All
Setting range: 0 to +100000000
Data size:
32-bit
Parameters
Address: 0126H
0127H
Address: 0128H
0129H
8
8-39