P5.097■
Default:
0
Unit:
-
Format:
HEX
Settings:
Write to this parameter to issue a macro command; read this parameter to examine the execution result
of a macro command.
If the command issues 0x0003, 0x1003 is returned if successful; and 0xF03X if unsuccessful (depending
on the command description). If you execute a command that is not supported, the failure code 0xF001 is
returned.
The command codes are listed in the following tables:
Command code 0x0003
Macro parameters
Read the return value of
P5.097 after executing
the macro
Command code 0x0004
Macro parameters
Read the return value of
P5.097 after executing
the macro
Motion control macro command: issue command /
execution result
Parameter and data array protection: password setting, protection activation
This function can only be executed prior to activating the parameter protection function.
When the protection function is activated, the failure code is returned if this function is
executed repeatedly.
P5.093 = parameter groups 5, 6, and 7 are write-protected
0: no protection
1: enable protection
P5.094 = read protection range of parameter and data array (-1 to 7)
-1: parameter groups 5, 6, 7 and data array are readable
0: parameter groups 5, 6, 7 and data array are unreadable
1: parameter groups 5, 6, 7 and data array #100 - 799 are unreadable
2: parameter groups 5, 6, 7 and data array #200 - 799 are unreadable
3: parameter groups 5, 6, 7 and data array #300 - 799 are unreadable
4: parameter groups 5, 6, 7 and data array #400 - 799 are unreadable
5: parameter groups 5, 6, 7 and data array #500 - 799 are unreadable
6: parameter groups 5, 6, 7 and data array #600 - 799 are unreadable
7: parameter groups 5, 6, 7 are unreadable, but data array is readable
P5.095 = set new password (1 - 16777215)
P5.096 = confirm new password (1 - 16777215)
0xF031: protection function is activated and cannot be set repeatedly
0xF032: wrong password setting, P5.095 does not equal P5.096
0xF033: password value exceeds the allowable range (1 - 16777215)
0xF034: protection range P5.094 exceeds the allowable range (-1 to 7)
0xF035: protection level P5.093 exceeds the allowable range (0 - 1)
Parameter and data array protection: unlock protection
This function can only be executed when the protection function is activated. When
the protection function is unlocked, the failure code is returned if this function is
executed repeatedly. If the wrong password is entered, failure code 0xEnnn is
returned. nnn indicates the remaining attempts to enter the password. The number
decrements by 1 after each failed attempt. When the number displays 0, it indicates
the maximum number of failed password attempts has been reached and it is locked.
You can only reset all parameters (P2.008 = 10) to unlock.
P5.096 = enter password (1 - 16777215)
Control mode: All
Setting range: 0 - 0x099F
Data size:
16-bit
Success code
0x1003
Failure code
Success code
0x1004
Parameters
Address: 05C2H
05C3H
8
8-145