6.2.6 Low-pass filter

6
Refer to Chapter 8 for detailed descriptions of the relevant parameter.
Parameter
P1.008

6.2.7 Timing diagram of PR mode

In PR mode, the Position command is issued with the DI signals (POS0 – POS6 and CTRG) for
CN1. Refer to Section 6.2.2 for information about the DI signal and its selected register.
The timing diagrams are shown below.
Note: Cmd_OK is on when the PR command completes; TPOS is on when the error is smaller than value
set by P1.054; MC_OK is on when Cmd_OK and TPOS are both on.
6-10
Position command smoothing constant (low-pass filter)
Internal
register
(PR#0 - 99)
Motion
curve
(Speed)
on
POS 0
POS 1
External
POS 2
DI
CTRG
on
SON
Set the response time with
Cmd_OK
Internal
TPOS
DO
MC_OK
Function
PR#1
PR#2
1 ms
off
off
on
off
P2.009
on
off
off
on
off
on
ASDA-A3
PR#4
off
off
on