ASDA-A3
Example:
Set P2.094 = 0x11 to enable the first set.
1.
Set P2.094 = 0x12 to enable the second set.
2.
Set P2.094 = 0x13 to enable the first and second sets simultaneously.
3.
P1.090
Default:
4000
Unit:
0.1 Hz
Format:
DEC
Settings:
Resonance frequency for the first set of low frequency vibration elimination.
P1.091
Default:
10
Unit:
0.1 dB
Format:
DEC
Settings:
Attenuation rate for the first set of low frequency vibration elimination.
P1.092
Default:
4000
Unit:
0.1 Hz
Format:
DEC
Settings:
Anti-resonance frequency for the second set of low frequency vibration elimination. The setting method
is the same as the first set of vibration elimination (P1.089).
P1.093
Default:
4000
Unit:
0.1 Hz
Format:
DEC
Settings:
Resonance frequency for the second set of low frequency vibration elimination.
First set of vibration elimination - resonance frequency
First set of vibration elimination - resonance difference
Second set of vibration elimination - anti-resonance
frequency
Second set of vibration elimination - resonance frequency
Control mode: PT / PR
Setting range: 10 - 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 - 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 - 4000
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 - 4000
Data size:
16-bit
Parameters
Address: 01B4H
01B5H
Address: 01B6H
01B7H
Address: 01B8H
01B9H
Address: 01BAH
01BBH