ASDA-A3
P2.043
Default:
1000
Unit:
Hz
Format:
DEC
Settings:
The second setting for resonance frequency. This function is disabled if P2.044 is 0.
P2.044
Default:
0
Unit:
-dB
Format:
DEC
Settings:
The second Notch filter attenuation level. A value of 5 indicates -5 dB. Set this parameter to 0 to disable
the Notch filter.
P2.045
Default:
1000
Unit:
Hz
Format:
DEC
Settings:
The third setting for resonance frequency. This function is disabled if P2.046 is 0.
P2.046
Default:
0
Unit:
-dB
Format:
DEC
Settings:
The third Notch filter attenuation level. A value of 5 indicates -5 dB. Set this parameter to 0 to disable the
Notch filter.
Notch filter frequency (2)
Notch filter attenuation level (2)
Notch filter frequency (3)
Notch filter attenuation level (3)
Control mode: All
Setting range: 50 - 5000
Data size:
16-bit
Control mode: All
Setting range: 0 - 40
Data size:
16-bit
Control mode: All
Setting range: 50 - 5000
Data size:
16-bit
Control mode: All
Setting range: 0 - 40
Data size:
16-bit
Parameters
Address: 0256H
0257H
Address: 0258H
0259H
Address: 025AH
025BH
Address: 025CH
025DH