Delta ASDA-A3 Series User Manual page 264

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
You can use the panel, communication, or ASDA-Soft to read data from or write data to the data
array. Regardless of the methods, they are completed by parameter settings. The first
parameter group for reading and writing the data array is P5.011, P5.012, and P5.013. P5.011
specifies the address for reading and writing the data array. P5.012 and P5.013 are for reading
and writing the actual data contents. You can use both to read and write, but the behaviors after
reading and writing differ. Refer to Table 7.2.1.1 for more information. The second parameter
group for reading and writing the data array is P5.011 and P5.100 – P5.103. P5.011 specifies
the address for reading and writing the data array. P5.100 reads data from or writes data to the
data array address set by P5.011. P5.101 reads data from or writes data to the data array
address following the address set by P5.011. P5.102 and P5.103 work the same way. If the
address value accumulates and exceeds the maximum of 799, the returned address is 0.
You can find more details in Table 7.2.1.2.
Parameter
P5.011
Address for
reading / writing
Window for
reading / writing
P5.012
Window #1 for
reading / writing
P5.013
Window #2 for
reading / writing
Table 7.2.1.1 Group 1 - reading and writing the data array
Specify the address for reading from or writing to the data array
by
Behavior after reading
Value of P5.011 does not
Panel
Communication /
Value of P5.011 adds 1
ASDA-Soft
Panel
Value of P5.011 adds 1
Communication /
Value of P5.011 adds 1
ASDA-Soft
Description
Behavior after writing
Value of P5.011 adds 1
add 1
Value of P5.011 adds 1
Cannot be written with the
Value of P5.011 adds 1
Motion Control
drive panel
7-67
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecm-a3 series

Table of Contents