PR path setting: the compensation amount for the slave axis is stored in the PR number
7.
specified by P2.073.BA. When the slave axis requires compensation, the system can
trigger this PR path at the proper timing. When using the E-Cam phase alignment function,
set the following for the specified PR: [Point-to-Point Command], [INC Incremental
7
position], [OVLP: allow the next PR command to overlap the command that is currently
executed when decelerating], and the appropriate speed and acceleration. Setting the
position command is not required because it is automatically set by the E-Cam phase
alignment function.
E-Cam phase alignment setting: it is set by P2.076.X. P2.076.X Bit 0 enables or disables
8.
the alignment function. After this function is enabled, it starts operating as soon as the
servo drive receives the DI signal. P2.076.X Bit 1 sets whether to immediately trigger the
PR command and calls this PR command when the clutch disengages (P5.088.BA).
P2.076.X Bit 2 selects the phase alignment method depending on whether the mark is on
the compensated motion axis.