Delta ASDA-A3 Series User Manual page 785

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Troubleshooting
AL207 Parameter group of PR#8 is out of range
Trigger condition
and cause
13
Checking method
and corrective action
How to clear the
alarm?
AL209 Parameter number of PR#8 is out of range
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL213 Parameter setting of PR#8 is in error
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL215 Write parameters: read-only
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL217 Write parameters: parameter locked
Trigger condition
and cause
Checking method
and corrective action
13-40
Condition: parameter group of PR#8, P_Group, is out of range.
Cause: the group of PR#8 command source exceeds the range.
Write parameter using PR procedure: when the parameter group of command
source exceeds the range, check the group setting of the written parameters.
DI.ARST or set P0.001 to 0.
Condition: parameter number of PR#8 is out of range.
Cause: the number of PR#8 command source exceeds the range.
Write parameter using PR procedure: when the parameter number of command
source exceeds the range, check the set range of the number for the written
parameters.
DI.ARST or set P0.001 to 0.
Condition: when using PR#8 to write parameters, the parameter value is incorrect.
Cause: an error occurs when writing parameters with PR#8 command.
Make sure the parameter value is within the correct range.
DI.ARST or set P0.001 to 0.
Condition: when using the PR procedure to write parameters, the parameter is
read-only.
Cause: an error occurs when writing parameters with PR#8 command.
The specified parameter is read-only.
DI.ARST or set P0.001 to 0.
Condition: when using the PR procedure to write parameters, the parameter is
write-protected when the servo drive is on or the parameter's value exceeds the
range.
Cause: an error occurs when writing parameters with PR#8 command.
Write the parameters when the servo drive is off and make sure the parameter's
value is within the range.