Delta ASDA-A3 Series User Manual page 398

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
P0.055
Default:
0
Unit:
-
Format:
DEC
Settings:
Refer to the description of P0.054.
P0.056
Default:
0
Unit:
-
Format:
DEC
Settings:
Before using this function, set the digital output function to [0x2D] (second set of general range comparison)
and the monitoring items of P0.018. When the monitoring item value of P0.010 is within the range set by
P0.056 and P0.057, and after the filtering time set by P0.053.Y, this digital output status is on.
P0.057
Default:
0
Unit:
-
Format:
DEC
Settings:
Refer to the description of P0.056.
P0.058
Default:
0
Unit:
-
Format:
DEC
Settings:
Before using this function, set the digital output function to [0x2E] (third set of general range comparison)
and the monitoring items of P0.019. When the monitoring item value of P0.011 is within the range set by
P0.058 and P0.059, and after the filtering time set by P0.053.Z, this digital output status is on.
General range compare digital output - first upper limit
General range compare digital output - second lower limit
General range compare digital output - second upper limit
General range compare digital output - third lower limit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Parameters
Address: 006EH
006FH
Address: 0071H
0072H
Address: 0073H
0074H
Address: 0075H
0076H
8
8-25