ASDA-A3
P1.004
Default:
100
Unit:
% (full scale)
Format:
DEC
Settings:
Refer to P0.003 for the analog output setting.
Example 1:
If the requirement is for the motor to run at 1,000 rpm, which corresponds to 8V, and its maximum speed
is 5,000 rpm, then the setting is:
Required speed
P1.004 =
Maximum speed
Refer to the following examples for the motor's current speed and relative voltage output:
Motor speed
300 rpm
900 rpm
P1.005
Default:
100
Unit:
% (full scale)
Format:
DEC
Settings:
Refer to P0.003 for the analog output setting.
P1.006
Default:
0
Unit:
ms
Format:
DEC
Settings:
0: disable this function.
P1.007
Default:
0
Unit:
ms
Format:
DEC
Settings:
0: disable this function.
MON1 analog monitor output proportion
1000 rpm
×100% =
5000 rpm
Current speed
MON1 = 8V ×
Maximum speed×
Current speed
MON1 = 8V ×
Maximum speed×
MON2 analog monitor output proportion
Speed command smoothing constant (low-pass filter)
Torque command smoothing constant (low-pass filter)
Control mode: All
Setting range: 0 - 100
Data size:
16-bit
×100% = 20%
MON1 analog monitor output
300 rpm
×100% = 8V ×
P1.004
5000 rpm×
100
900 rpm
×100% = 8V ×
P1.004
5000 rpm×
100
Control mode: All
Setting range: 0 - 100
Data size:
16-bit
Control mode: S / Sz
Setting range: 0 - 1000
Data size:
16-bit
Control mode: T / Tz
Setting range: 0 - 1000
Data size:
16-bit
Address: 0108H
0109H
×100% = 2.4V
20
100
×100% = 7.2V
20
100
Address: 010AH
010BH
Address: 010CH
010DH
Address: 010EH
010FH
Parameters
8
8-33