Delta ASDA-A3 Series User Manual page 368

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
Empty pack prevention:
3.
When the empty pack sensor does not detect the packing content, it uses the DI event
trigger to enable the function to avoid empty packs.
PR#60
PR#61
PR#62
PR#60 (I)
Write
Event 1 On
DLY=[0] 0 ms
P5.093=
0x00000000
Rising-edge triggers Event 1 to set the macro parameter P5.093 to 0.
Executes Macro #10 to immediately stop the wrap feeder operation for one cycle.
Inhibits the reverse operation and enables the filter when the acceleration or
deceleration time is less than 340 ms.
PR#61 (I)
PR#62 (I)
Write
DLY=[0] 0 ms
DLY=[0] 0 ms
P1.022=0x1022
P5.097=0x0010
Motion Control
Write
7-171