ASDA-A3
P4.004★
Default:
0x00000000
Unit:
-
Format:
HEX
Settings:
The fifth to last abnormal status record.
Low word (LXXXX): the alarm number.
High word (hYYYY): the error code corresponding to CANopen / DMCNET.
P4.005
Default:
20
Unit:
rpm
Format:
DEC
Settings:
The control methods are as follows:
1. Operation test:
After the JOG speed is set by P4.005, the panel displays the JOG symbol. Pressing the UP key
controls the JOG operation in the positive direction; pressing the DOWN key controls the JOG
operation in the negative direction. Stop pressing to stop the JOG operation. If there is any error in
this setting, then the motor cannot operate. The maximum JOG speed is the maximum speed of the
servo motor.
2. DI control:
If you set the DI to JOGU and JOGD (refer to Table 8.1), then the JOG operation in the positive or
negative direction is controlled with this DI.
3. Communication control:
4999: JOG operation in clockwise
Note: when using communication to write values, and the frequency is high, set P2.030 to 5.
P4.006■
Default:
0x0000
Unit:
-
Format:
HEX
Fault record (N-4)
Servo motor JOG control
1 - 5000: JOG speed
direction
Digital output register (readable and writable)
Control mode: All
Setting range: -
Data size:
32-bit
Control mode: All
0 - 5000 (rotary motor)
Setting range:
0 - 50000 (linear motor)
Data size:
16-bit
4998: JOG operation in
counterclockwise direction
0: stop operation
Control mode: All
Setting range: 0 - 0xFFFF
Data size:
16-bit
Parameters
Address: 0408H
0409H
Address: 040AH
040BH
Address: 040CH
040DH
8
8-109