Delta ASDA-A3 Series User Manual page 82

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
You can input the Pulse command with the open collector or line driver. The maximum input
pulse for the line driver is 4 Mpps and 200 kpps for the open collector.
C3-1: the source for the pulse input is open collector NPN type equipment, which uses the
external power supply.
Note: this is not supported by the A3-F.
C3-2: the source for the pulse input is open collector PNP type equipment, which uses the
external power supply.
Controller
Note: this is not supported by the A3-F.
Controller
+
DC
24V
-
SG
+
24V
-
SG
Servo drive
35
Pull-hi_S
1.5 KΩ
Max. pulse input frequency:
200 Kpps
51 Ω
Sign
51 Ω
37
/Sign
39
Pull-hi_P
Max. pulse input frequency:
1.5 KΩ
200 Kpps
51 Ω
Pulse
51 Ω
41
/Pulse
Servo drive
35
Pull-hi_S
1.5 kΩ
Max. pulse input frequency:
51 Ω
Sign
51 Ω
37
/Sign
Pull-hi_P
39
Max. pulse input frequency:
1.5 kΩ
200 Kpps
51 Ω
Pulse
51 Ω
41
/Pulse
200 Kpps
Wiring