Delta ASDA-A3 Series User Manual page 782

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
AL123 Data size error occurs when accessing CANopen PDO
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL124 Data range error occurs when accessing CANopen PDO
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL125 CANopen PDO object is read-only and write-protected
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL126 Specified object does not support PDO mapping
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL127 CANopen PDO is write-protected when servo drive is on
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
AL128 Error occurs when reading CANopen PDO from EEPROM
Trigger condition
and cause
Checking method
and corrective action
How to clear the
alarm?
Data length in the message does not match the length of the specified object.
Check if the data length for PDO mapping is changed when the servo drive
receives or sends PDO.
NMT: reset node or 0x6040 fault reset.
The data value in the message is out of range for the specified object.
Check if the written range is wrong when the servo drive receives or sends PDO.
NMT: reset node or 0x6040 fault reset.
The specified object in the message is read-only and write-protected.
Check if the object for the PDO mapping is read-only.
NMT: reset node or 0x6040 fault reset.
The specified object in the message does not support PDO mapping.
Check if the specified object allows PDO mapping when PDO is receiving or
sending.
NMT: reset node or 0x6040 fault reset.
The specified object in the message is write-protected when the servo drive is on.
Make sure no PDO is written when the servo drive is on.
NMT: reset node or 0x6040 fault reset.
An error occurs when loading the default value from ROM at start-up. All objects of
CAN automatically return to the default value.
When PDO is receiving or sending, check if the error occurs because the specified
object reads from EEPROM.
NMT: reset node or 0x6040 fault reset.
Troubleshooting
13
13-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecm-a3 series

Table of Contents