Delta ASDA-A3 Series User Manual page 392

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
When PH = PL = P, it indicates that the content of P0.025 includes one 32-bit parameter.
2.
Example: Target: set P6.010 to 0x00050064 in the mapping parameter.
P0.036
Default:
-
Unit:
-
Format:
HEX
Settings:
mappin g p arameter
mappin g p arameter
P0.037
Default:
-
Unit:
-
Format:
HEX
Settings:
High bit
Position of
P0.037
mapping p arameter
Content of
P0.027
mappin g p arameter
Write: in the mapping content, set P0.025 to 0x00050064, and the values of P2.003 and
P2.005 are:
P0.025
P2.003
Setting: set both the high bit and low bit of P0.035 to 060A (P6.010).
Thus, P6.010 = 0x060A060A.
P6.010
P0.035
Write: in the mapping content, set P0.025 to 0x00050064 and P6.010 changes
immediately.
Target setting for mapping parameter P0.026
Position of
Position of
mappin g p arameter
Content of
Content of
mappin g p arameter
Target setting for mapping parameter P0.027
Low bit
Position of
mapping p arameter
Content of
mappin g p arameter
0005
0064
P2.005
0005
0064
P6.010
Control mode: All
Setting range: Determined by the communication
Data size:
Control mode: All
Setting range: Determined by the communication
Data size:
Address: 0048H
0049H
address of the parameter group
32-bit
Address: 004AH
004BH
address of the parameter group
32-bit