Delta ASDA-A3 Series User Manual page 338

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
Motion Control
Combine E-Cam curves: use "Manually create a table". The E-cam curve has a total of
6.
400 position points, so you need to set the E-Cam segment number N (P5.082) to 400.
Click Create Table and a table of 400 position points is generated. Right-click on the table,
select Import points, fill in "1" to "300" in the pop-up window, select the first section of the
7
curve, then click OK. Follow the same steps as previous, but fill in "301" to "400" in the
pop-up window, select the second section of the curve, then click Draw to complete the
E-Cam curve of the fully engaged mode.
7-141