ASDA-A3
P5.019
Default:
1.000000
Unit:
0.000001 times, which is 1 / (10^6)
Format:
DEC
Example:
1100000 = 1.1 times
Settings:
Use this parameter to magnify or reduce the E-Cam table without changing its value.
Example: the data in the table is 0, 10, 20, 30, 40, 20, magnification x 2.000000 equals the data: 0, 20, 40,
60, 80, 40, magnification x 1.000000.
This enables the operation of E-Cam with the same pulse frequency of the master axis. Magnification
enlarges both the route of E-Cam operation and the speed.
Note: this parameter can be set at any time, but the time when it becomes effective is determined by P5.088.X [Bit 2].
P5.020
Default:
200
Unit:
ms
Format:
DEC
Settings:
The duration of acceleration and deceleration in PR mode, which is the length of time to accelerate from
0 to 3,000 rpm.
P5.021
Default:
300
Unit:
ms
Format:
DEC
Settings:
Refer to P5.020 for the acceleration / deceleration time in PR mode.
P5.022
Default:
500
Unit:
ms
Format:
DEC
Settings:
Refer to P5.020 for the acceleration / deceleration time in PR mode.
E-Cam curve scaling
Acceleration / deceleration time (Number #0)
Acceleration / deceleration time (Number #1)
Acceleration / deceleration time (Number #2)
Control mode: PR
Setting range: -2147.000000 to +2147.000000
Data size:
32-bit
Control mode: PR
Setting range: 1 - 65500
Data size:
16-bit
Control mode: PR
Setting range: 1 - 65500
Data size:
16-bit
Control mode: PR
Setting range: 1 - 65500
Data size:
16-bit
Parameters
Address: 0526H
0527H
Address: 0528H
0529H
Address: 052AH
052BH
Address: 052CH
052DH
8
8-121