Parameters
Settings:
Set the value for monitoring in P0.017 with the drive panel or communication. Refer to P0.002.
The communication port reads the communication address to get the status.
8
For example, if you set P0.017 to 3 to access P0.009, the panel displays the total number of feedback
pulses of the motor encoder. If accessing the data through MODBUS communication, it reads two 16-bit
values (0012H and 0013H) as a single 32-bit value. (0013H : 0012H) = (Hi-word : Low-word). Set P0.002
to 23 and the panel displays VAR-1 as the value of P0.009.
P0.010★■
Default:
Unit:
Format:
Settings:
Set the value to be monitored in P0.018 through the drive panel or communication. Please refer to
P0.002. The communication port reads the communication address to get the status. Set P0.002 to 24
and the panel displays VAR-2 as the value of P0.010.
P0.011★■
Default:
Unit:
Format:
Settings:
Set the value to be monitored in P0.019 through the drive panel or communication. Please refer to
P0.002. The communication port reads the communication address to get the status. Set P0.002 to 25
and the panel displays VAR-3 as the value of P0.011.
P0.012★■
Default:
Unit:
Format:
Settings:
Set the value to be monitored in P0.020 through the drive panel or communication. Please refer to
P0.002. The communication port reads the communication address to get the status. Set P0.002 to 26
and the panel displays VAR-4 as the value of P0.012.
8-14
Status monitoring register 2
-
-
DEC
Status monitoring register 3
-
-
DEC
Status monitoring register 4
-
-
DEC
Control mode: All
Setting range: -
Data size:
32-bit
Control mode: All
Setting range: -
Data size:
32-bit
Control mode: All
Setting range: -
Data size:
32-bit
ASDA-A3
Address: 0014H
0015H
Address: 0016H
0017H
Address: 0018H
0019H