Delta ASDA-A3 Series User Manual page 492

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
P5.011■
Default:
0
Unit:
-
Format:
DEC
Settings:
Specify the address in the data array when reading and writing data. Refer to Chapter 7 for detailed
instructions.
P5.012■
Default:
0
Unit:
-
Format:
DEC
Settings:
Window #1: when reading the parameter with the panel, the value set by P5.011 does not add 1,
but reading or writing by other methods adds 1. Refer to Section 7.2.1 Data array for detailed instructions.
P5.013■
Default:
0
Unit:
-
Format:
DEC
Settings:
Window #2: when reading the parameter with the panel or reading and writing the parameter through
communication, the value set by P5.011 adds 1, but the panel is write-protected. Refer to Section 7.2.1
Data array for detailed instructions.
P5.014
P5.015■
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
This parameter allows you to write data to the target continuously through communication.
U
Z
Y
Data array - address for reading and writing
Data array - window #1 for reading and writing
Data array - window #2 for reading and writing
Reserved
PATH#1 - PATH#2 volatile setting
X
Control mode: All
Setting range: 0 to (value set by P5.010 minus 1)
Data size:
16-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
Control mode: PR
Setting range: 0x0000 - 0x0011
Data size:
16-bit
Parameters
Address: 0516H
0517H
Address: 0518H
0519H
Address: 051AH
051BH
Address: 051EH
051FH
8
8-119