Delta ASDA-A3 Series User Manual page 397

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

Parameters
P0.053
Default:
Unit:
8
Format:
Settings:
X: first filter time
Y: second filter time
Z: third filter time
U: fourth filter time
Note: the minimum filter time is 1 ms (set value 0 = 1 ms; 1 = 2 ms; 2 = 3 ms; ...; F = 16 ms).
Example of the first filter:
P0.054
Default:
Unit:
Format:
Settings:
Before using this function, set the digital output function to [0x2C] (first set of general range comparison)
and the monitoring items of P0.017. When the monitoring item value of P0.009 is within the range set by
P0.054 and P0.055, and after the filtering time set by P0.053.X, this digital output status is on.
8-24
General range compare digital output - filter time
0x0000
-
HEX
General range compare digital output - first lower limit
0
-
DEC
Control mode: All
Setting range: 0x0000 - 0xFFFF
Data size:
16-bit
Control mode: All
Setting range: -2147483648 to +2147483647
Data size:
32-bit
ASDA-A3
Address: 006AH
006BH
Address: 006CH
006DH