When installing an external regenerative resistor, connect the resistor to P3 and C contacts, and
P3 and D contacts are left open. It is recommended that you choose external regenerative
resistors of the resistance values specified in the table on page 2-18. For easy calculation of the
2
regenerative resistor capacity, except for the energy consumed by IGBT, there are two ways
provided to calculate the capacity according to the selected rotary motor.
Rotary motor:
Selecting the regenerative energy
Calculation of the regenerative energy when there is no external torque
(a)
If the motor is making a reciprocating motion, the regenerative resistor consumes the excess
return energy. Refer to the following table when calculating and selecting the required
regenerative resistor.
Servo drive (kW)
Low
inertia
Medium
inertia
2-20
(1) Moving direction of the object; (2) Direction of torque;
(3) Regenerative energy generated when the motor decelerates
Motor
0.1
ECM-A3L-C
1
040F
0.1
ECM-A3L-C
1
0401
0.2
ECM-A3L-C
1
0602
0.4
ECM-A3L-C
1
0604
0.4
ECM-A3L-C
1
0804
ECM-A3L-C
1
0807
0.75
1.0
ECMC-C
1
1010
1.0
ECMC-E
1
1310
1.5
ECMC-E
1
1315
2.0
ECMC-E
1
1320
2.0
ECMC-E
1
1820
Rotor inertia
motor decelerates from
2
(× 10
kg.m
)
-4
2
3
1
0.0229
2
3
1
0.04
2
3
1
0.09
2
3
1
0.15
2
3
1
0.352
2
3
1
0.559
2
3
2.65
2
3
8.41
2
3
11.2
2
3
14.6
2
3
34.7
Regenerative energy
generated when the
regenerative
energy of the
the rated speed to 0
capacitance
without load Eo (joule)
0.11
0.20
0.45
0.74
1.74
2.76
13.1
18.48
24.62
32.09
76.26
ASDA-A3
Maximum
Ec (joule)
8.42
8.42
8.42
8.42
8.42
26.21
26.21
26.21
26.21
34.94
34.94