Delta ASDA-A3 Series User Manual page 582

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
PM.035▲
Operation
Panel / software
interface:
Default:
-
Unit:
ohm
Setting range: 0.000 - 65.535
Format:
Two decimals
Example:
1.5 = 1.5 ohm
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor.
PM.036▲
Operation
Panel / software
interface:
Default:
-
Unit:
mH
Setting range: 0.00 - 655.35
Format:
Two decimals
Example:
1.5 = 1.5 mH
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor.
PM.037
PM.038▲
Operation
Panel / software
interface:
Default:
-
Unit:
Vrms/rpm
Setting range: 0.0000 - 2.2876
Format:
Four decimals
Example:
1.5 = 1.5 Vrms/rpm
Settings:
Input the correct information according to the specifications of the third-party permanent-magnet rotary
motor.
Permanent-magnet rotary motor phase resistance
Communication
-
0.001 ohm
0 - 65535
DEC
1500 = 1.5 ohm
Permanent-magnet rotary motor phase inductance
Communication
-
0.01 mH
0 - 65535
DEC
150 = 1.5 mH
Reserved
Permanent-magnet rotary motor back electromotive
force constant
Communication
-
0.0001 Vrms/rpm
0 - 22876
DEC
15000 = 1.5 Vrms/rpm
Address: FD46H
Applicable
Permanent-magnet rotary motor
motor:
Data size:
32-bit
Address: FD48H
Applicable
Permanent-magnet rotary motor
motor:
Data size:
32-bit
Address: FD4CH
Applicable
Permanent-magnet rotary motor
motor:
Data size:
32-bit
Parameters
FD47H
FD49H
FD4DH
8-209
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecm-a3 series

Table of Contents