Parameters
P4.021
Default:
Unit:
8
Format:
Settings:
Offset adjustment value (cannot reset). The function must be enabled by setting P2.008.
P4.022
Default:
Unit:
Format:
Settings:
Manually adjust the offset.
P4.023
Default:
Unit:
Format:
Settings:
Manually adjust the offset.
P4.024
Default:
Unit:
Format:
Settings:
When the voltage of the DC BUS is lower than P4.024* √ 2, the undervoltage alarm occurs.
8-114
Offset adjustment for analog monitor output (Ch2)
0
mV
DEC
Analog speed input offset
0
mV
DEC
Analog torque input offset
0
mV
DEC
Level of undervoltage error
160
V (rms)
DEC
Control mode: All
Setting range: -800 to 800
Data size:
16-bit
Control mode: S
Setting range: -5000 to 5000
Data size:
16-bit
Control mode: T
Setting range: -5000 to 5000
Data size:
16-bit
Control mode: All
Setting range: 140 - 190
Data size:
16-bit
ASDA-A3
Address: 042AH
042BH
Address: 042CH
042DH
Address: 042EH
042FH
Address: 0430H
0431H