Delta ASDA-A3 Series User Manual page 476

Hide thumbs Also See for ASDA-A3 Series:
Table of Contents

Advertisement

ASDA-A3
Definition of U value
0: use Delta's controller, such as PLC or HMI
3: use Delta's motion card
Note:
If this parameter is set through CANopen, only Z can be set and the others remain unchanged.
1.
The communication speed of USB is set at 1.0 M bps and cannot be changed.
2.
After the Z value is set, cycle the power to take effect.
3.
P3.002
Default:
0x0006
Unit:
-
Format:
HEX
Settings:
Definition of each value:
0: 7, N, 2 (MODBUS, ASCII)
3: 8, N, 2 (MODBUS, ASCII)
6: 8, N, 2 (MODBUS, RTU)
P3.003
Default:
0x0000
Unit:
-
Format:
HEX
Settings:
Definition of each value:
0: display warning and let motor continue operating.
1: display warning and let motor decelerate to a stop. Deceleration time is set in P5.003.B.
P3.004
Default:
0
Unit:
sec
Format:
DEC
Settings:
If the value is not 0, communication timeout is enabled immediately. To disable this function, set the value
to 0.
P3.005
Communication protocol
1: 7, E, 1 (MODBUS, ASCII)
4: 8, E, 1 (MODBUS, ASCII)
7: 8, E, 1 (MODBUS, RTU)
Communication error handling
Communication timeout
Reserved
Control mode: All
Setting range: 0x0000 - 0x0008
Data size:
16-bit
2: 7, O, 1 (MODBUS, ASCII)
5: 8, O, 1 (MODBUS, ASCII)
8: 8, O, 1 (MODBUS, RTU)
Control mode: All
Setting range: 0x0000 - 0x0001
Data size:
16-bit
Control mode: All
Setting range: 0 - 20
Data size:
16-bit
Parameters
Address: 0304H
0305H
Address: 0306H
0307H
Address: 0308H
0309H
8
8-103