Parameters
P1.023
Default:
Unit:
8
Format:
Settings:
When using the Compare function, add the translation value to the data array to be used as the actual
comparison data:
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Example:
If the data array for comparison is DATA_ARRAY[100] = 2000; P1.023 = 40; P1.024 = 0;
then the actual comparison value = 2000 + 40 = 2040.
Note: monitor CMP_DATA with the monitoring variable 037(25h).
P1.024■
Default:
Unit:
Format:
Settings:
When using the Compare function, add the translation value to the data array to be used as the actual
comparison data:
CMP_DATA = DATA_ARRAY[*] + P1.023 + P1.024
Note:
If P1.019.Z [Bit 0] = 1, this parameter automatically resets after taking effect.
1.
Monitor CMP_DATA with the monitoring variable 037(25h).
2.
P1.025
Default:
Unit:
Format:
Example:
Settings:
Sets the first low-frequency vibration suppression frequency. When you set P1.026 to 0, the first
low-frequency vibration suppression filter is disabled.
8-42
Compare - data translation (non-volatile)
0
Pulse unit of compare source
DEC
Compare - data translation (reset automatically)
0
Pulse unit of compare source
DEC
Low-frequency vibration suppression frequency (1)
1000
0.1 Hz
DEC
150 = 15 Hz
Control mode: All
Setting range: -10000000 to +100000000
Data size:
32-bit
Control mode: All
Setting range: -32768 to +32767
Data size:
16-bit
Control mode: PT / PR
Setting range: 10 - 1000
Data size:
16-bit
ASDA-A3
Address: 012EH
012FH
Address: 0130H
0131H
Address: 0132H
0133H