Motion Control
to the table. When you set n points for the E-Cam segment number, the table has n+1
columns.
Fill in the slave axis positions: fill in the corresponding position in PUU for each segment.
3.
Click Draw. The software automatically generates a simulated E-Cam curve and cam
7
position, speed, and acceleration curve. When manually creating the table, pay more
attention to the speed continuation of the slave axis to avoid machine vibration or motor
overload caused by speed discontinuation.
Download E-Cam curve: once the E-Cam curve is confirmed, click Download Table to
4.
write the E-Cam curve to the data array. If you click Write Table Data to EEPROM, the
data array is written to EEPROM and is non-volatile.
When using a third-party software (such as Excel) to create the table, save all position data as a
text file (.txt) and use the Space, Tab, Enter keys, vertical bar "|", or a comma "," to separate the
position data of each point.
If you start the E-CAM Editor in ASDA-Soft and choose to manually create the table, specify the
E-Cam segment number (P5.082), and click Create Table, then the table displays the E-Cam
phase corresponding to the E-Cam segments. Right-click the table, select Import points, and
then click Browse after the window for importing point data appears. Open the text file that has
been saved, and select the separator you use in the saved file for Separate symbol. Then, click
OK to complete loading the text file. Next, click Draw to have the software generate the E-Cam
curve based on the E-Cam positions. You can also export the position data as a text file.
7-96
Figure 7.3.4.3 ASDA-Soft Manual setting interface for creating E-Cam table