Download Print this page

Subaru LEGACY 2006 Manual page 3716

Hide thumbs Also See for LEGACY 2006:

Advertisement

asieps_tobira.book 32 ページ 2009年10月26日 月曜日 午前9時16分
AT Shift Lock Solenoid and "P" Range Switch
CONTROL SYSTEMS
C: INSPECTION
Step
1
CHECK SHIFT LOCK SOLENOID.
Measure the resistance of shift lock solenoid
connector terminals.
Terminals
No. 4 — No. 3:
2
CHECK SHIFT LOCK SOLENOID.
Connect the battery to shift lock solenoid con-
nector terminal, and then operate the solenoid.
Terminals
No. 3 (+) — No. 4 (–):
3
CHECK "P" RANGE SWITCH.
1) Move the select lever to "P" range.
2) Measure the resistance between "P" range
switch connector terminals.
Terminals
No. 1 — No. 2:
4
CHECK "P" RANGE SWITCH.
1) Set the select lever to other than "P" range.
2) Measure the resistance between "P" range
switch connector terminals.
Terminals
No. 1 — No. 2:
Check
Is the resistance between 12
Go to step 2.
— 18 Ω?
Go to step 3.
Does the shift lock solenoid
operate normally?
Is the resistance less than 1
Go to step 4.
Ω?
Is the resistance more than 1
Normal operation
MΩ?
CS-32
Yes
No
Replace the shift
lock solenoid.
Replace the shift
lock solenoid.
Replace the "P"
range switch.
Replace the "P"
range switch.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Legacy 2007