Download Print this page

Subaru LEGACY 2006 Manual page 3826

Hide thumbs Also See for LEGACY 2006:

Advertisement

asieps_tobira.book 29 ページ 2009年10月26日 月曜日 午前9時16分
3) Connect the operating rod to brake pedal with
clevis pin and snap pin.
(2)
(4)
(1) Nut
(2) Clevis pin
(3) Snap pin
(4) Operating rod
NOTE:
Apply a thin coat of SUNLIGHT 2 (Part No.
003602010) to the clevis pin.
4) Connect the vacuum hose to the brake booster.
5) After replacing the O-ring, install the master cyl-
inder to brake booster.
(1) Primary piston
(2) O-ring
(3) Do not install the O-ring on this groove.
6) Connect the brake pipes to the master cylinder.
7) Connect the connector of the brake fluid level
gauge.
Brake Booster
(1)
(3)
BR-00073
(3)
(2)
(1)
BR-00363
BR-29
8) Measure the clearance between the threaded
end of the stop light switch and the stopper.
If it is not within the specification, adjust it by adjust-
ing the position of the stop light switch. <Ref. to BR-
41, ADJUSTMENT, Stop Light Switch.>
CAUTION:
Be careful not to rotate the stop light switch.
Stop light switch clearance A:
0.3 mm (0.012 in)
9) Apply grease to the operating rod connecting pin
to prevent it from wear.
10) Bleed air from brake system.
Tightening torque (air bleeder screw):
8 N·m (0.8 kgf-m, 5.8 ft-lb)
11) Perform a road test to make sure the brakes do
not drag.
C: INSPECTION
1. OPERATION CHECK (WITHOUT GAUG-
ES)
CAUTION:
When checking operation, be sure to apply the
parking brake securely.
• Check without gauges
This method can not determine exactly what part is
defective. But it is possible to identify the outline of
the defect by performing the check according to the
following procedures.
BRAKE
A
BR-00079

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Legacy 2007