ENGINE GENERAL INFORMATION 1A-17
Leakage Test
1. Run the engine to be the coolant temperature
80 °C (176 °F).
2. Remove the fuel injection nozzle.
3. Open the coolant reservoir.
4. Check the coolant level and replenish if necessary.
5. Open the oil filler cap.
6. Remove the air cleaner cover and element.
7. Position the piston at TDC.
8. Install the connector (1) and connection piece (2).
9. Calibrate the tester and connect the connection
YAD1A150
hose (3)
10. Pressurize with compressed air and compare the
pressure changes with permissible pressure
leakage.
11. If permissible pressure leakage is out of standard,
check followings :
- Intake and exhaust lines.
- Sounds in oil filler area.
- Air bubbles in radiator coolant.
12. Do pressure leakage test for the remaining
cylinders according to the firing order.
firing order: 1-2-4-5-3
13. Remove the tester.
14. Close the coolant reservoir cap and oil filler cap.
15. Install the air cleaner element and cover.
16. Install the fuel injection nozzle.