Shifter Status Register (Flexio_Shiftstat) - NXP Semiconductors MKL27Z128VFM4 Reference Manual

Table of Contents

Advertisement

Field
0
Software reset is disabled
1
Software reset is enabled, all FlexIO registers except the Control Register are reset.
0
FlexIO Enable
FLEXEN
0
FlexIO module is disabled.
1
FlexIO module is enabled.

39.3.4 Shifter Status Register (FLEXIO_SHIFTSTAT)

.
Address: 4005_F000h base + 10h offset = 4005_F010h
Bit
31
30
29
28
27
26
R
W
0
0
0
0
0
0
Reset
Field
31–4
This field is reserved.
Reserved
This read-only field is reserved and always has the value 0.
SSF
Shifter Status Flag
The shifter status flag is updated when one of the following events occurs:
For SMOD=Receive, the status flag is set when SHIFTBUF has been loaded with data from Shifter
(SHIFTBUF is full), and the status flag is cleared when SHIFTBUF register is read.
For SMOD=Transmit, the status flag is set when SHIFTBUF data has been transferred to the Shifter
(SHIFTBUF is empty) or when initially configured for SMOD=Transmit, and the status flag is cleared when
the SHIFTBUF register is written.
For SMOD=Match Store, the status flag is set when a match has occured between SHIFTBUF and Shifter,
and the status flag is cleared when the SHIFTBUF register is read.
For SMOD=Match Continuous, returns the current match result between the SHIFTBUF and Shifter.
The status flag can also be cleared by writing a logic one to the flag for all modes except Match
Continuous.
0
Status flag is clear
1
Status flag is set
Freescale Semiconductor, Inc.
FLEXIO_CTRL field descriptions (continued)
25
24
23
22
21
20
19
18
0
0
0
0
0
0
0
0
FLEXIO_SHIFTSTAT field descriptions
KL27 Sub-Family Reference Manual , Rev. 5, 01/2016
Description
17
16
15
14
13
12
11
0
0
0
0
0
0
0
0
Description
Chapter 39 FlexIO
10
9
8
7
6
5
4
3
0
0
0
0
0
0
0
0
2
1
0
SSF
w1c
0
0
0