23. Setting DSP smooth PAD mode
MG-COT > SET SMOOTH_PAD_MG P1
Smooth PAD Mode setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
24. Setting RTP Start Port
MG-COT > SET STARTPORT P1
RTP Start Port Number setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
Port number must be the even number. RTCP port number is assigned to start port number + 1. (odd num-
Note:
ber)
MG-COT Card [SCA-6COTA/SCA-6COTC]
Line 1: Enter a value of smooth PAD(1-
Line 2: Result is shown.
Line 1: Enter the number of RTP Start
Line 2: Result is shown.
VOL.2-597
5, OFF).
OFF=Set smooth PAD mode to
OFF
1=2.0dBm (default)
2=-5.2dBm
3=-2.1dBm
4=0dBm
5=-4.2dBm
Port in the range of 1024-64510
(default=1024).