If payload type G.711 is specified to more than two priorities in PRI1 through PRI4, assign different pay-
Note:
load size to each priority.
When payload types G.723.1 (5.3K → 6.3K) and G.723.1 (6.3K → 5.3K) are to be assigned on the same
•
terminal, specify the same value to the payload size of both types.
•
It is not necessary to assign the payload type/size to the whole priorities. Specifying the first priority
only is allowed.
•
For available payload type/payload size, refer to Peripheral Equipment Description, Volume 1, Chapter
2, "3.1.1 Bandwidth Required for Voice Traffic."
Setting of PAD: Click the check box to assign the PAD data manually. If not checked, default value 0 is
KIND2: Specify the PAD value of 8LC Card in the range of 0-3.
KIND3: Specify the PAD No. of IPPAD in the range of 0-15.
Setting of Echo Canceller: Click the check box to assign the Echo Canceller data, and select one of the ra-
When the same value is assigned to both "A LOC-ID" and "B LOC-ID" parameters, select either "A EC-
Note:
ON/B EC-ON" or "A EC-OFF/B EC-OFF."
8LC Card needs to be rebooted after station data is assigned to reflect the changed data. Confirm that there
Note:
is no conversation in progress when rebooting.
8LC Card [SCA-8LCA/SCA-8LCA-EMEA/SCA-8LCC/SCA-8LCC-EMEA]
•
60 milliseconds
applied.
•
No PAD control (determined by ASYD, SYS1, INDEX 4, bit5 (5 dB PAD))
•
PAD OFF (0 dB)
•
3 dB
•
6 dB
PAD value is determined by this PAD No. (0-15) and the setting of SW10-6/7 on IPPAD
card. Refer to the Circuit Card Description for more details.
dio buttons.
•
A EC-ON/B EC-ON
•
A EC-ON/B EC-OFF
•
A EC-OFF/B EC-ON
•
A EC-OFF/B EC-OFF