3.
Setting Caller ID Send Wait Timer:
MC(SIP)> SET CID_SEND_WAIT
CallerID Send Wait Timer (5-20)[6]:10
CallerID Send Wait Timer setting succeeded.
The maximum value of Caller ID send wait timer for each specification is as follows:
Note:
- ETSI Caller ID 20 (2000 milliseconds)
- Bellcore Caller ID:15 (1500 milliseconds)
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
4.
Setting CODEC Coefficiency:
MC(SIP)> SET CODEC_COEF
CODEC Coefficient CH No. (0-7): 0
CODEC Coefficient (0-5)[0]: 0
CODEC Coefficient (CH00) setting succeeded.
The setting values are shown in the following table.
Note 1:
North America
RESISTER
600Ω
600Ω
Australia
RESISTER
220Ω+(820Ω//120nF)
220Ω+(820Ω//120nF)
600Ω
8LC Card [SCA-8LCA/SCA-8LCA-EMEA/SCA-8LCC/SCA-8LCC-EMEA]
KIND OF BNW
600Ω
350Ω+(1000Ω//210nF)
KIND OF BNW
600Ω
220Ω+(820Ω//120nF)
600Ω
VOL.2-171
Enter the Caller ID send wait timer [5-20]
(default=6)
*5-20 (×100 milliseconds)
Result is shown.
Enter the Line Number [0-7]
Enter the setting value [0-5] (default=0) Note 1
Result is shown.
SETTING VALUE
0 (default)
SETTING VALUE
0 (default)
1
1
2

Hide quick links: