8.3 Startup MCMG and Basic Tests
This section explains procedures for startup and basic tests. Follow the procedure below depending on the reg-
istration destination.
STEP 1: Data Assignment by PCPro
When registering to Internal PHI-BRI
1. Internal PHI-BRI Data Assignment
2. MG Data Assignment
3. Internal PHE Data Assignment
4. MC Data Assignment
STEP 2: Terminal Software Setting on Maintenance Console
1. Connection between PC (maintenance console) and CONSOLE Connector
2. Terminal Software Activation
3. Setting of Terminal Software
STEP 3: Power ON
STEP 4: Configuration Command Assignment
1. Selection whether to use DHCP server
2. Network Data Assignment
STEP 5: Cable Connection
1. Connection between MCMG and LAN
2. Connection between C.O. lines and MG
STEP 6: Basic Test Procedures
1. Basic Connection Test
2. Alarm Information Check
3. PFT Switching Test
END
Be sure to assign MG data before assigning MC data.
Note 1:
When registering to SP-PHI
1. Internal PHE Data Assignment
Note 1
2. SP-PHI Data Assignment
3. MG Data Assignment
4. MC Data Assignment
VOL.2-426
MCMG Card [SCA-7COTA]
Note 1