NEC Univerge sv8500 Manual page 952

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

18. Setting Host Name of MG-COT Card
MG-COT(SIP) > SET OWN_NAME P1
Host Name setting succeeded.
The designated Host Name cannot be applied when Proprietary Protocol mode. Assign the SP mode before
Note:
executing this Host Name setting.
Host name cannot be used when DHCP is assigned ENABLE or DNS is assigned DISABLE. Before assign-
Note:
ing the host name, be sure to execute "SET DHCP DISABLE" and "SET DNS_SW".
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
19. Setting Release Signal
MG-COT > SET RELEASE_SIGNAL P1
Release Signal setting succeeded.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
20. Setting signaling port number for SIP
MG-COT(SIP) > SET SIGNALING_PORT_NO P1
Signaling Port Number setting succeeded.
The designated Signaling Port Number cannot be applied when Proprietary Protocol mode. Assign the SP
Note:
mode before executing this Signaling Port Number setting.
To make this assignment effective, use the SAVE command, and restart before exiting the maintenance com-
Note:
mand.
21. Setting QoS for SIP signaling session
When ToS is selected in QoS setting type:
MG-COT(SIP)> SET SIGNALING_QOS
QOS (TOS/DIFFSERV) [TOS]: TOS
Line1: Enter the host name of MG-COT
Line 2: Result is shown.
Line1: Select Release Signal Setting.
Line 2: Result is shown.
Line1: Enter the Port Number used for
Line 2: Result is shown.
Line 2: Select QoS setting type
VOL.2-699
MG-COT Card [SCA-6COTB]
Card in full-domain format
within 63 characters of
alphanumerics, ". (period)", and
"- (hyphen)".
OFF=Invalid (default)
ON=Valid
SP-PHI. (default=5060)
(default=TOS)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents