SET COMMAND
1.
Setting CODEC Coefficiency
MG-COT > SET CODEC_COEF_MG P1 P2
CODEC Coefficient(CH00) setting succeeded.
The setting values are shown in the following table. Set appropriate values. Setting value "2" is assigned
Note:
when the product is shipped. Change the data if required.
•
North America
RESISTER
600Ω+2.16μF
600Ω+2.16μF
600Ω+2.16μF
900Ω+2.16μF
900Ω+2.16μF
900Ω+2.16μF
•
Australia
RESISTER
220Ω+(820Ω//120nF)
220Ω+(820Ω//120nF)
600Ω
•
Brazil
RESISTER
900Ω
900Ω
MG-COT Card [SCA-6COTA/SCA-6COTC]
Line 1: Enter the Line Number 0-5. And
Line 2: Result is shown.
KIND OF BNW
600Ω+2.16μF
600Ω
350Ω+(1000Ω//210nF)
900Ω+2.16μF
900Ω
800Ω//(100Ω/+50nF)
KIND OF BNW
220Ω+(820Ω//120nF)
600Ω
600Ω
KIND OF BNW
800Ω//50nF
900Ω
VOL.2-586
then, enter the setting value
(default is 2) after the space.
SETTING VALUE
0 (default)
1
2
3
4
5
SETTING VALUE
0 (default)
1
2
SETTING VALUE
0 (default)
1