NEC Univerge sv8500 Manual page 1233

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Δ
Δ
21. SET
TCS_E1_1
This command is used to specify E1 Dch data. To make this assignment effective, it is required to execute
the "SAVE" command and to restart before exiting the maintenance command.
COMMAND 1
MG -PRI> SET TCS_E1_1
Dch Control
Dch Mode
Dch Signal Logic
Dch-1 Drop/Insert
Dch-2 Drop/Insert
Drop/Insert Mode
Data Transfer Speed
Drop/Insert Time Slot ( 1-31:16 ): 16
Dch Signaling Set (0/1:0):0
set value is 0x9080
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
COMMAND 2
MG -PRI> SET TCS_E1_1 9080
set value is 0x9080
setting complete.
In order to make a setup reflect, re-starting
is required after saving a configuration file
by SAVE command.
[P1]
( 0/1:1 ): 1
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0/1:1 ): 1
( 0/1:0 ): 0
( 0/1:0 ): 0
( 0-2:0 ): 0
VOL.2-980
P1-Specify a set value
0000-FFFF= Set value (default value: 9080)
When P1 is omitted→COMMAND 1
When P1 is specified→COMMAND 2
<COMMAND 1>
1) Enable/Disable Dch Control
0/1=Disable/Enable (default)
2) Enable/Disable Dch Mode
0=User (default)
1=Network
Check connectivity for network in advance if you
will use Network mode.
3) Specify Dch Signal Logic
0=Positive Logic (default)
1=Negative Logic
4) Enable/Disable Dch 1
0/1=Disable/Enable (default)
5) Enable/Disable Dch 2
0 (fixed)
6) Drop/Insert Mode
0=Fixed value (default)
1=Set value
7) Specify Data Transfer Speed
0=64K (default)
1=56K
2=48K
8) Specify the number of Time Slots
1-31= Number of Time Slots (default value: 16)
9) Specify Dch Signaling Set
0 (fixed)
A command is executed, and the result is displayed.
<COMMAND 2>
A command is executed, and the result is displayed.
MG-PRI/PRA